raised floor - traducción al Inglés

ELEVATED FLOOR ABOVE A SOLID SUBSTRATE TO CREATE A VOID FOR MECHANICAL AND ELECTRICAL SERVICES
Raised flooring; Computer floor; Tile-lifter; Tile lifter; Elevated Floor; Elevated floor; False floor; Pedestal flooring; Raised Access Computer Floor; Access flooring
  • An alternative raised floor application with disposable formworks from job site in Turkey

raised floor         
(n.) = suelo alzado
Ex: There is still the need to have the centralised computer room with special air-conditioning, power supply and raised floor.
raised         
MUSICAL ARTIST
Raised; Hailey Whitters discography; Everything She Ain't
(adj.) = elevado, en relieve
Ex: The cords themselves could be placed either outside the backs of the folded sheets, where they would show as raised bands across the spine of the book, or in slots sawn into the folds to give the book a flat back.
----
* raised floor = suelo alzado
floorcloth         
  • Floorcloth in a geometric tile pattern from George Harrison and Co., possibly 1880s
HEAVY TEXTILE, PAINTED OR STAINED, FORMERLY USED AS A DECORATIVE FLOOR COVERING
Floor-cloth; Floorcloths; Floor-cloths; Floor cloth; Floor cloths
bayeta

Definición

raised beach
¦ noun Geology a former beach now above water level owing to changes since its formation.

Wikipedia

Raised floor

A raised floor (also raised flooring, access floor(ing), or raised-access computer floor) provides an elevated structural floor above a solid substrate (often a concrete slab) to create a hidden void for the passage of mechanical and electrical services. Raised floors are widely used in modern office buildings, and in specialized areas such as command centers, Information technology data centers and computer rooms, where there is a requirement to route mechanical services and cables, wiring, and electrical supply. Such flooring can be installed at varying heights from 2 inches (51 mm) to heights above 4 feet (1.2 m) to suit services that may be accommodated beneath. Additional structural support and lighting are often provided when a floor is raised enough for a person to crawl or even walk beneath.

In the U.S., underfloor air distribution is becoming a more common way to cool a building by using the void below the raised floor as a plenum chamber to distribute conditioned air, which has been done in Europe since the 1970s. In data centers, isolated air-conditioning zones are often associated with raised floors. Perforated tiles are traditionally placed beneath computer systems to direct conditioned air directly to them. In turn, the computing equipment is often designed to draw cooling air from below and exhaust into the room. An air conditioning unit then draws air from the room, cools it, and forces it beneath the raised floor, completing the cycle.

Above describes what has historically been perceived as raised floor and still serves the purpose for which it was originally designed. Decades later, an alternative approach to raised floor evolved to manage underfloor cable distribution for a wider range of applications where underfloor air distribution is not utilized. In 2009 a separate category of raised floor was established by Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC) to separate the similar, but very different, approaches to raised flooring. In this case the term raised floor includes low-profile fixed-height access flooring. Offices, classrooms, conference rooms, retail spaces, museums, studios, and more, have the primary need to quickly and easily accommodate changes of technology and floor plan configurations. Underfloor air distribution is not included in this approach since a plenum chamber is not created. The low-profile fixed-height distinction reflects the system's height ranges from as low as 1.6 to 2.75 inches (41 to 70 mm); and the floor panels are manufactured with integral support (not traditional pedestals and panels). Cabling channels are directly accessible under light-weight cover plates.